CLEARANCES TO COMBUSTIBLES
It is of utmost importance that the clearances to combustible materials be strictly adhered to during
installation of the stove. Refer to the tables below :
• Floortoceilingheightmustbeatleast7’(2.13m)inallcases.
• Donotplaceanycombustiblematerialwithin4’(1.2m)ofthefrontoftheunit.
• Theclearancebetweentheuepipeandawallarevalidonlyforverticalwallsandforverticalue
pipe.
• Thechimneyconnectormustnotpassthroughanatticorroofspace,closetorsimilarconcealed
space,aoor,oraceiling.
• ForCanadianinstallations,wherepassagethroughawall,orpartitionofcombustibleconstruction
is desired, the installation must conform to CAN/CSA-B365.
• Auepipecrossingacombustiblewallmusthaveaminimumclearanceof18”(457.2mm).
• Toreduceueclearancesfromcombustiblematerials,contactyourlocalsafetydepartment.
Single Wall Pipe
Model A B C D E F
3000
14
(358mm)
20
(508mm)
17.5
(445mm)
30.5
(775mm)
11
(279mm)
24
(610mm)